Comtech EF Data SLM-5650B Installation And Operation Manual page 366

Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Command or
Code and
Response to
Type
Qualifier)
RTC Date
DAY=
6 bytes
Eb/No Alarm
EBA=
4 bytes
Point
Equipment ID
N/A
17 bytes
Appendix C
Description of Arguments
Query
Command or Query.
A date in the form ddmmyy, where:
dd = day of the month (01 to 31),
mm = month (01 to 12)
yy = year (00 to 99)
Example: DAY = 240457 (April 24, 2057)
Command or Query.
Eb/No alarm point in dB, with a range between 0.1 and 20 dB.
Resolution = 0.1 dB.
Example: EBA = 12.3
Query only.
Unit returns information concerning the equipment identification,
and the option field, in the form aaaabcdefghijklmx where:
aaaa = defines the modem model number (565B = SLM-
5650B)
b = Advanced FEC:
1 = TPC
2 = TPC + LDPC
c = Reserved
d = Option Card:
0 = None
1 = G.703
2 = GigaBit Ethernet
3 = Reserved
4 = Network Processor
5 = LVDS
Response to
Command
DAY=
DAY?
DAY*
DAY#
EBA=
EBA?
EBA*
EBA#
N/A
C–38
SLM-5650B Satellite Modem
Revision 2
Query
Response to
(Instruction
Query
Code and
Qualifier)
DAY?
DAY=ddmmyy
(see Description
of Arguments)
EBA?
EBA=xx.x
(see Description
of Arguments)
EID?
EID=aaaabcdef
ghijklmx
(see Description
of Arguments)
MN-SLM-5650B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLM-5650B and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF