Comtech EF Data SLM-5650B Installation And Operation Manual page 344

Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Command or
Code and
Response to
Type
Qualifier)
Tx Clock Invert
TCI=
1 byte
Tx Clock Source
TCK=
1 byte
Tx
TCW=
1 byte
Reed-Solomon
Code Word
Appendix C
Description of Arguments
Query
Command or Query.
Invert Transmit Clock, where:
0 = Normal
1 = Inverted
Example: TCI=1 (selects Inverted TX Clock)
Command or Query.
Tx Clock Source, where:
x = Tx Clock Source:
0 = SCT
1 = Tx Terrestrial
Example: TCK=1 (selects Tx Terrestrial Clock Source)
Command or Query.
Tx RS encoding, where:
0 = RS(225,205,10)
1 = RS(219,201,9)
2 = RS(208,192,8)
3 = RS(194,178,8)
4 = RS(126,112,7)
5 = RS(220,200,10)
Depending on Modem mode, overhead type, and data rate, not all
selections will be valid.
Example: TCW = 0 (This is a 'don't care' if RS is Off under TRS)
C–16
SLM-5650B Satellite Modem
Query
Response to
Response to
(Instruction
Command
Query
Code and
Qualifier)
TCI =
TCI?
TCI=x
TCI?
(see Description of
Arguments)
TCI*
TCI#
TCK=
TCK?
TCK=x
TCK?
(see Description of
Arguments)
TCK*
TCK#
TCW=
TCW?
TCW=x
TCW?
(see Description of
Arguments)
TCW*
TCW#