Comtech EF Data SLM-5650B Installation And Operation Manual page 361

Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Command or
Code and
Response to
Type
Qualifier)
CnC-APC State
(cont)
Buffer Fill State
N/A
2 bytes
Appendix C
Description of Arguments
Query
(IF)
09 = OK(Partial) – Distant power approaches minimum value
(L-Band)
10 = OK(Partial) – Distant power approaches maximum value
11 = OK(Partial) – Distant power approaches limit set by max
power level increase
12 = OK(Partial) – Incomplete
13 = No APC Frame Sync
14 = CnC Ratio Problem
15 = Local Eb/No too high
16 = Distant Eb/No too high
17 = Distant End ReBalance failed
18 = Distant End No Response
19 = Fail-Calculate Mismatch
20 = CnC Ratio too high
21 = Please run again
22 = APC is active
23 = Local margin too low
24 = Distant margin too low
25 = Rx Data Rate < 64 kbps
26 = Tx Data Rate < 64 kbps
27 = Local RSL too low
28 = Distant RSL too low
29 = Unrecognized Modem
Example: APS = 00
Query only.
xx = value of the buffer fill state, between 1 to 99%.
Returns 00 if demodulator is unlocked.
Example: BFS = 33 (selects 33%)
Response to
Command
N/A
C–33
SLM-5650B Satellite Modem
Revision 2
Query
Response to
(Instruction
Query
Code and
Qualifier)
BFS?
BFS=xx
(see Description
of Arguments)
MN-SLM-5650B

Advertisement

Table of Contents
loading

Table of Contents