Config: Transec; Config: Aho; Config: Odu - Comtech EF Data SLM-5650B Installation And Operation Manual

Table of Contents

Advertisement

5.2.3.5

CONFIG: TRANSEC

TRANSEC: State: Encrypted
Module IP Address
Use the arrow keys to select State, Module IP Address, or Gateway, and then press
[ENT].
Option
State
Module IP
Address
Gateway
5.2.3.6

CONFIG: AHO

This feature is a future option and not available at this time.
5.2.3.7

CONFIG: ODU

ODU: LNB Power:Off
Low Current:000
Use the arrow keys to select Mode, State, PwrOffset, or Delay, and then press [ENT].
Setting
LNB Power
Monitor
Low Current
High Current
Front Panel Operation
Gateway
Settings
Select Encrypted or Bypass.
Set the TRANSEC Module's Management IP Address and subnet mask length.
Set the TRANSEC Module's IP Gateway.
Monitor
High Current: 000
Function
Off, 13VDC, 18VDC, 19VDC, or 24VDC.
View LNB voltage and LNB current draw.
Configure Low Current alarm threshold.
Configure High Current alarm threshold.
(E)
(E)
5–27
SLM-5650B Satellite Modem
Revision 2
MN-SLM-5650B