Command
Arguments for
Parameter
(Instruction
Command or
Code and
Response to
Type
Qualifier)
Configure FAST
Options (cont)
Circuit ID String
CID=
24 bytes
1 byte
Carrier-in-Carrier
CNM=
(CnC) Mode
Carrier Only Test
COM=
1 byte
Modes
Appendix C
Description of Arguments
Query
i = Bridged Point to Multipoint:
0 = Not Installed
1 = Installed
j = Spare
k = Reserved
l = Reserved
m = Spare
n = Reserved0
0 = Not Installed
1 = Installed
o = Spare
p = Reserved
Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed
length of 24 characters.
Valid characters include: Space ( ) * + – , . / 0 9 and A thru Z
Command or Query.
CnC Mode of Operation, where:
0 = Off
1 = On
Example: CNM = 0
Command or Query.
Test Mode, where:
0 = Normal Mode (no test)
1 = Tx CW
2 = Tx Alternating 1,0 Pattern
Example: COM = 1 (CW Mode)
Response to
Command
CID=
CID?
CID*
CID#
CNM=
CNM?
CNM*
CNM#
COM=
COM?
COM*
COM#
C–36
SLM-5650B Satellite Modem
Revision 2
Query
Response to
(Instruction
Query
Code and
Qualifier)
CID?
CID=xxxxxxxxx
xxxxxxxxxxxxxx x
(see Description
of Arguments)
CNM?
CNM=x
(see Description
of Arguments)
COM?
COM=x
(see Description
of Arguments)
MN-SLM-5650B
Need help?
Do you have a question about the SLM-5650B and is the answer not in the manual?
Questions and answers