KVM over IP User Manual
Though it synchronizes the time automatically, NTP does not update the time
periodically without user's processing.
Time Zone is an offset time of GMT. You have to select the time zone first and
then perform time sync via NTP because the switch will combine this time
zone offset and updated NTP time to come out the local time, otherwise, you
will not able to get the correct time. The switch supports configurable time
zone from –12 to +13 step 1 hour.
Default Time zone: +8 Hrs.
 Parameter description:
Server 1 to 5:
Provide the NTP IPv4 or IPv6 address of this switch. IPv6 address is in 128-bit
records represented as eight fields of up to four hexadecimal digits with a colon
separating each field (:). For example, 'fe80::215:c5ff:fe03:4dc7'. The symbol
'::' is a special syntax that can be used as a shorthand way of representing
multiple 16-bit groups of contiguous zeros; but it can only appear once. It can
also represent a legally valid IPv4 address. For example, '::192.1.2.34'.
 Buttons
These buttons are displayed on the SNTP page:
Apply:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved values.