Chapter 4. Port Management
Transmission Time:
The interval between each loop protection PDU sent on each port. Valid values
are 1 to 10 seconds.
Shutdown Time:
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 10
to 604800 seconds (7 days).
Port Configuration
Port:
The switch port number of the port.
Enable:
Controls whether loop protection is enabled on this switch port
Action:
Configures the action performed when a loop is detected on a port. Valid values
are Shutdown Port, Shutdown Port and Log or Log Only.
Tx Mode:
Controls whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
 Buttons
Apply:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved values.