ATEN ES0152 User Manual page 297

52-port gbe poe managed switch
Hide thumbs Also See for ES0152:
Table of Contents

Advertisement

Chapter 12. Security
RADIUS-assigned QoS provides a means to centrally control the traffic class
to which traffic coming from a successfully authenticated supplicant is
assigned on the switch. The RADIUS server must be configured to transmit
special RADIUS attributes to take advantage of this feature (see RADIUS-
Assigned QoS Enabled below for a detailed description).
The "RADIUS-Assigned QoS Enabled" checkbox provides a quick way to
globally enable/disable RADIUS-server assigned QoS Class functionality.
When checked, the individual ports' ditto setting determine whether RADIUS-
assigned QoS Class is enabled on that port. When unchecked, RADIUS-server
assigned QoS Class is disabled on all ports.
RADIUS-Assigned VLAN Enabled:
RADIUS-assigned VLAN provides a means to centrally control the VLAN on
which a successfully authenticated supplicant is placed on the switch.
Incoming traffic will be classified to and switched on the RADIUS-assigned
VLAN. The RADIUS server must be configured to transmit special RADIUS
attributes to take advantage of this feature (see RADIUS-Assigned VLAN
Enabled below for a detailed description).
The "RADIUS-Assigned VLAN Enabled" checkbox provides a quick way to
globally enable/disable RADIUS-server assigned VLAN functionality. When
checked, the individual ports' ditto setting determine whether RADIUS-
assigned VLAN is enabled on that port. When unchecked, RADIUS-server
assigned VLAN is disabled on all ports.
Guest VLAN Enabled:
A Guest VLAN is a special VLAN - typically with limited network access - on
which 802.1X-unaware clients are placed after a network administrator-
defined timeout. The switch follows a set of rules for entering and leaving the
Guest VLAN as listed below.
The "Guest VLAN Enabled" checkbox provides a quick way to globally
enable/disable Guest VLAN functionality. When checked, the individual ports'
ditto setting determines whether the port can be moved into Guest VLAN.
When unchecked, the ability to move to the Guest VLAN is disabled on all
ports.
Guest VLAN ID:
This is the value that a port's Port VLAN ID is set to if a port is moved into the
Guest VLAN. It is only changeable if the Guest VLAN option
is globally enabled.
Valid values are in the range [1; 4094].
Max. Reauth. Count: