The IPv4 address of the interface in dotted decimal notation.
If DHCP is enabled, this field is not used. The field may also be left blank if
IPv4 operation on the interface is not desired.
Subnet Mask:
User IP subnet mask of the entry.
Gateway:
The IP address of the IP gateway. Valid format is dotted decimal notation or a
valid IPv6 notation. Gateway and Network must be of the same type.
DNS Server:
This setting controls the DNS name resolution done by the switch.
There are four servers available for configuration, and the index of the server
presents the preference (less index has higher priority) in doing DNS name
resolution.
The following modes are supported:
 No DNS server
No DNS server will be used.
 Configured IPv4
Explicitly provide the valid IPv4 unicast address of the DNS Server
in dotted decimal notation.
Make sure the configured DNS server could be reachable (e.g. via PING)
for activating DNS service.
 Configured IPv6
Explicitly provide the valid IPv6 unicast (except linklocal) address of the
DNS Server.
Make sure the configured DNS server could be reachable (e.g. via PING6)
for activating DNS service.
 From any DHCPv4 interfaces
The first DNS server offered from a DHCPv4 lease to a DHCPv4-enabled
interface will be used.
 From this DHCPv4 interface
Specify from which DHCPv4-enabled interface a provided DNS server
should be preferred.
 From any DHCPv6 interfaces