KVM over IP User Manual
There is a unicast storm policer, multicast storm policer, and a broadcast storm
policer.
These only affect flooded frames, i.e. frames with a (VLAN ID, DMAC) pair
not present in the MAC Address table.
Frame Type:
The frame type for which the configuration below applies.
Enable:
Enable or disable the global storm policer for the given frame type.
Rate:
Controls the rate for the global storm policer. This value is restricted to 10-
13128147 when "Unit" is fps or kbps, and 1-13128 when "Unit" is kfps or
Mbps. The rate is internally rounded up to the nearest value supported by the
global storm policer. Supported rates are divisible by 10 fps or 25 kbps.
Unit:
Controls the unit of measure for the global storm policer rate as fps, kfps, kbps
or Mbps.
Port Storm Policer Configuration Help
Port storm policers for all switch ports are configured on this page.
There is a storm policer for known and unknown unicast frames, known and
unknown broadcast frames and unknown (flooded) unicast, multicast and
broadcast frames.
Port:
The port number for which the configuration below applies.
Enable:
Enable or disable the storm policer for this switch port.
Rate:
Controls the rate for the port storm policer. This value is restricted to 10-
13128147 when "Unit" is fps or kbps, and 1-13128 when "Unit" is kfps or
Mbps. The rate is internally rounded up to the nearest value supported by the
port storm policer. Supported rates are divisible by 10 fps or 25 kbps.
Unit:
Controls the unit of measure for the port storm policer rate as fps, kfps, kbps or
Mbps.