ATEN ES0152 User Manual page 331

52-port gbe poe managed switch
Hide thumbs Also See for ES0152:
Table of Contents

Advertisement

Chapter 12. Security
6. If you want to cancel the setting then you need to click the Reset button. It
will revert to previously saved values.
 Parameter description:
Global Configuration
These setting are common for all of the RADIUS servers.
Timeout:
Timeout is the number of seconds, in the range 1 to 1000, to wait for a reply
from a RADIUS server before retransmitting the request.
Retransmit:
Retransmit is the number of times, in the range 1 to 1000, a RADIUS request
is retransmitted to a server that is not responding. If the server has not
responded after the last retransmit it is considered to be dead.
Deadtime:
Deadtime, which can be set to a number between 0 to 1440 minutes, is the
period during which the switch will not send new requests to a server that has
failed to respond to a previous request. This will stop the switch from
continually trying to contact a server that it has already determined as dead.
Setting the Deadtime to a value greater than 0 (zero) will enable this feature,
but only if more than one server has been configured.
Key:
The secret key - up to 63 characters long - shared between the RADIUS server
and the switch.
NAS-IP-Address:
The IPv4 address to be used as attribute 4 in RADIUS Access-Request packets.
If this field is left blank, the IP address of the outgoing interface is used.
NAS-IPv6-Address:
The IPv6 address to be used as attribute 95 in RADIUS Access-Request
packets. If this field is left blank, the IP address of the outgoing interface is
used.
NAS-Identifier:
The identifier - up to 255 characters long - to be used as attribute 32 in
RADIUS Access-Request packets. If this field is left blank, the NAS-Identifier
is not included in the packet.