ATEN ES0152 User Manual page 123

52-port gbe poe managed switch
Hide thumbs Also See for ES0152:
Table of Contents

Advertisement

Chapter 5. PoE Management (ES0152P
Startup Time:
After startup time, device will enable auto checking. Default: 30, range: 30-60
sec.
Interval Time(sec):
Device will send checking message to PD each interval time. Default: 30,
range: 10-120 sec.
Retry Time:
When PoE port can't ping the PD, it will retry to send detection again. When
the third time, it will trigger failure action. Default: 3, range: 1-5.
Failure Log:
Failure loggings counter.
Failure Action:
The action when the third fail detection.
Nothing: Keep Ping the remote PD but does nothing further.
Reboot: Cut off the power of the PoE port, make PD rebooted.
Reboot time (sec):
When PD has been rebooted, the PoE port restored power after the specified
time. Default: 15, range: 3-120 sec.
 Buttons
Apply:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved values.
109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es0152p

Table of Contents