ATEN ES0152 User Manual page 347

52-port gbe poe managed switch
Hide thumbs Also See for ES0152:
Table of Contents

Advertisement

Chapter 13. Access Control
Action:
Select whether forwarding is permitted ("Permit") or denied ("Deny"). The
default value is "Permit".
Rate Limiter ID:
Select which rate limiter to apply on this port. The allowed values are Disabled
or the values 1 through 16. The default value is "Disabled".
Port Redirect:
Select which port frames are redirected on. The allowed values are Disabled or
a specific port number and it can't be set when action is permitted. The default
value is "Disabled".
Mirror
Specify the mirror operation of this port. The allowed values are:
Enabled: Frames received on the port are mirrored.
Disabled: Frames received on the port are not mirrored.
The default value is "Disabled".
Logging:
Specify the logging operation of this port. The allowed values are:
Enabled: Frames received on the port are stored in the System Log.
Disabled: Frames received on the port are not logged.
The default value is "Disabled". Please note that the System Log memory size
and logging rate is limited.
Shutdown:
Specify the port shut down operation of this port. The allowed values are:
Enabled: If a frame is received on the port, the port will be disabled.
Disabled: Port shut down is disabled.
The default value is "Disabled".
State:
Specify the port state of this port. The allowed values are:
Enabled: To reopen ports by changing the volatile port configuration of the
ACL user module.
Disabled: To close ports by changing the volatile port configuration of the ACL
user module.
333