14.Clear Memory Mode

A: OPERATION
1. SUBARU SELECT MONITOR (NORMAL
MODE)
1) On the «Main Menu» display screen, select the
{2. Each System Check} and press the [YES] key.
2) On the «System Selection Menu» display
screen, select the {Engine Control System} and
press the [YES] key.
3) Press the [YES] key after displayed the informa-
tion of engine type.
4) On the «Engine Diagnosis» display screen, se-
lect the {Clear Memory} and press the [YES] key.
5) When the `Done' and `Turn Ignition Switch OFF'
are shown on the display screen, turn the Subaru
Select Monitor and ignition switch to OFF.
NOTE:
• After the memory has been cleared, the ISC
must be initialized. To do this, turn the ignition
switch to the ON position. Wait 3 seconds before
starting the engine.
• For detailed operation procedure, refer to the
SUBARU SELECT MONITOR OPERATION MAN-
UAL.
2. SUBARU SELECT MONITOR (OBD
MODE)
1) On the «Main Menu» display screen, select the
{2. Each System Check} and press the [YES] key.
2) On the «System Selection Menu» display
screen, select the {Engine Control System} and
press the [YES] key.
3) Press the [YES] key after displayed the informa-
tion of engine type.
4) On the «Engine Diagnosis» display screen, se-
lect the {OBD System} and press the [YES] key.
5) On the «OBD Menu» display screen, select the
{4. Diagnosis Code(s) Cleared} and press the
[YES] key.
6) When the `Clear Diagnostic Code?' is shown on
the display screen, press the [YES] key.
7) Turn Subaru Select Monitor and ignition switch
to OFF.
NOTE:
• After the memory has been cleared, the idle air
control solenoid valve must be initialized. To do
this, turn the ignition switch to the ON position. Wait
3 seconds before starting the engine.
• For detailed operation procedure, refer to the
SUBARU SELECT MONITOR OPERATION MAN-
UAL.
CLEAR MEMORY MODE
3. OBD-II GENERAL SCAN TOOL
For clear memory procedures using the OBD-II
general scan tool, refer to the OBD-II General Scan
Tool Instruction Manual.
After the memory has been cleared, the idle air
control solenoid valve must be initialized. To do
this, turn the ignition switch to the ON position. Wait
3 seconds before starting the engine.