EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)
5. Purge Control Solenoid Valve
A: REMOVAL
1) Disconnect battery ground cable.
2) Remove bolt which installs purge control sole-
noid valve onto intake manifold.
3) Take out purge control solenoid valve through
the bottom of the intake manifold.
4) Disconnect connector and hoses from purge
control solenoid valve.
PURGE CONTROL SOLENOID VALVE
FU-00009
EC-00039
EC-00040
EC(H4SOw/oOBD)-8
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
16 N·m (1.6 kgf-m, 11.6 ft-lb)
CAUTION:
Carefully connect the evaporation hoses.
A
(A) To fuel pipe
(B) To throttle body
C: INSPECTION
Make sure hoses are not cracked or loose.
EC-00039
B
FU-00285