AIR INTAKE ACTUATOR
AIR INTAKE ACTUATOR REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Remove the glove compartment. (See GLOVE COMPARTMENT REMOVAL/INSTALLATION .)
3. Remove the keyless control module. (See KEYLESS CONTROL MODULE
REMOVAL/INSTALLATION .)
4. Remove in the order indicated in the table.
1 Air intake actuator connector
2 Air intake actuator
5. Install in the reverse order of removal.
AIR INTAKE ACTUATOR INSPECTION
1. Connect battery positive voltage to air intake actuator terminal A (or C), and ground to terminal C (or
A), and then verify that the air intake actuator operates as shown in the table.
If the operation condition is not normal, replace the air intake actuator.
•