When replacing only the PCM: After verifying that the security light goes out, turn the ignition
switch to the LOCK position. (Procedure completed)
When replacing only the keyless control module: After verifying that the security light
illuminates for 3 s or more , turn the ignition switch to the LOCK position, remove key 1, and
then go to the next step.
13. Using key 2, turn the ignition switch to the ON position.
14. Verify that the security light illuminates for approx. 3 s and then goes out.
15. After verifying that the security light goes out, turn the ignition switch to the LOCK position using key
2, and then remove key 2.
16. If an additional key needs to be registered, repeat Steps 1315 in the same manner as key 2. Steps
1315 must be performed within 1 min for each key. If the ignition switch is maintained in the ON
position for 1 min or more , key registration according to Steps 1315 will not be possible. If this
occurs, refer to " No.1 Additional Key Registration Procedure (Using Two Valid Keys) " to register any
additional keys.
No.6 Security Access Procedure
NOTE:
Security access must be performed when performing the following functions: "Program Additional
Ignition Key", "Ignition key ID number Erase", "Customer Spare Key Programming Enable/Disable"
and "Parameter Reset".
Procedure
1. Connect the WDS or equivalent to the DLC-2.
2. Select "Body/Security/PATS function" from the screen menu of the WDS or equivalent.
3. Security access is started and the WDS displays "Outcode".