EVAPORATOR TEMPERATURE SENSOR
EVAPORATOR TEMPERATURE SENSOR REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Remove the glove compartment. (See GLOVE COMPARTMENT REMOVAL/INSTALLATION .)
3. Remove the keyless control module. (See KEYLESS CONTROL MODULE
REMOVAL/INSTALLATION .)
4. Remove in the order indicated in the table.
1 Evaporator temperature sensor connector
2 Evaporator temperature sensor
5. Install in the reverse order of removal.
(w)
RX-8 - HVAC
Page 31