Ford Electric Ranger 2001 Manual page 502

Hide thumbs Also See for Electric Ranger 2001:
Table of Contents

Advertisement

414-03A-99
REMOVAL AND INSTALLATION (Continued)
High Voltage/Traction Battery
3.
the traction battery is 312 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4. Remove the contactor box harness bracket.
5. NOTE: The battery control module (BCM) is
held in position with strips of Velcro
Remove the BCM.
1 Loosen the four bolts and disconnect the
2 Remove the BCM.
WARNING: The nominal voltage of
100-00.
four multi-pin connectors from the BCM.
2001 Ranger EV, 01/2001