414-03B-80
DIAGNOSIS AND TESTING (Continued)
PINPOINT TEST A: ALL HIGH-VOLTAGE AUXILIARY LOAD SYSTEMS DO NOT OPERATE
WARNING: The traction battery contains high-voltage components
and wiring. High-voltage insulated safety gloves and face shield must be
worn when carrying out the following steps. Failure to follow this
warning may result in severe personal injury or death.
• Connect Traction Battery High-Voltage Service Cord to high-voltage
auxiliary load in-line C1935F on the traction battery support tray and in-line
C1935M.
NOTE: Contactor box C3985 is mounted on the passenger side of the BCM.
• With key OFF, disconnect contactor box C3985 and measure the voltage
between the R wire on contactor box C3985 and chassis ground.
• Is the voltage greater than 10 volts?
GENERAL PROCEDURES
Traction Battery Module Replacement
Special Tool(s)
Battery Post Torque Wrench
307-026
Battery Terminal Cap Opener
418-F215
In-Line Bypass Battery Module
418-F210
(Continued)
High Voltage/Traction Battery — Nickel Metal Hydride
TEST STEP
No =
Special Tool(s)
New Generation STAR (NGS)
Tester or equivalent
418-F048 (007-00500)
Traction Battery High-Voltage
Lockout and Diagnostic Tool
418-F207
(Continued)
414-03B-80
ACTION TO TAKE
REPLACE high-voltage
harness 14B326 between
traction battery support tray
in-line C1935F and
contactor box C3985.
2001 Ranger EV, 01/2001