414-03B-176
DISASSEMBLY AND ASSEMBLY (Continued)
Item
1
Flow Through Blower Housing
2
Independent Observer Module (IOM)
3
Battery Control Module (BCM)
4
Recirculating Blower Assembly
5
Contactor Box Assembly (CBA)
(Continued)
High Voltage/Traction Battery — Nickel Metal Hydride
Description
Item
6
76 Pin Connector
7
Battery Tray
8
Battery Modules
9
Two-Pin High Voltage Connector
Disassembly
1. Remove the traction battery. Refer to
Battery.
2. Remove the traction battery cover.
1 Remove the 22 bolts.
2 Remove the cover.
WARNING: The nominal voltage of
3.
the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
100-00.
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4.
CAUTION: Disconnect only one HVJ
at a time.
Disconnect the HVJs from the contactor box.
Open the cap.
Remove and discard the nut.