414-03A-131
REMOVAL AND INSTALLATION (Continued)
Traction Battery High Voltage Fuse (250A)
Special Tool(s)
Battery Terminal Cap Opener
418-F215
High Voltage/Traction Battery
Installation
1. The lower traction battery heating element is
located in the bottom of the traction battery
tray. The entire traction battery must be
disassembled in order to remove and install the
heating element. Refer to the traction battery
assembly procedure in this section.
Removal
1. Remove the traction battery. Refer to
Battery.
2.
the traction battery is 312 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
WARNING: The nominal voltage of
100-00.
2001 Ranger EV, 01/2001
414-03A-131