Ford Electric Ranger 2001 Manual page 775

Hide thumbs Also See for Electric Ranger 2001:
Table of Contents

Advertisement

414-03B-172
REMOVAL AND INSTALLATION (Continued)
High Voltage/Traction Battery — Nickel Metal Hydride
3.
WARNING: The nominal voltage of
the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
100-00.
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4. Disconnect the independent observer module
(IOM) electrical connector.
1 Loosen the bolt.
2 Unclip the connector.
5. Remove the IOM.
1 Remove the bolts.
2 Remove the IOM.
414-03B-172