100-05-7
GENERAL PROCEDURES (Continued)
Traction Battery Two-Pin High-Voltage Connector
Special Tool(s)
Traction Battery High Voltage
Lockout and Diagnostic Tool
418-F207
Standard Service Procedures
Connect
1. To connect, reverse the disconnect procedure.
Disconnect
1.
battery voltage is 300 volts DC. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury of death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the rubber insulating gloves.
3 Wear the face shield.
2. Disconnect the auxiliary battery ground cable.
3. Raise and support the vehicle. Refer to
100-02.
4. Remove the cross bar.
1 Remove the bolts.
2 Remove the cross bar.
WARNING: The nominal traction
100-00.
2001 Ranger EV, 01/2001
100-05-7
Section

Hide quick links: