Ford Electric Ranger 2001 Manual page 20

Hide thumbs Also See for Electric Ranger 2001:
Table of Contents

Advertisement

100-05-6
GENERAL PROCEDURES (Continued)
Traction Battery Auxiliary Load High-Voltage Connector
Standard Service Procedures
13. NOTE: For Postal Ranger EV.
Close the charger inlet access door.
Disconnect
1.
battery voltage is 300 volts DC. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury of death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the rubber insulating gloves.
3 Wear the face shield.
2. If connected, disconnect the vehicle from the
power control station (PCS).
3. Disconnect the auxiliary battery ground cable.
4. Raise and support the vehicle. Refer to
100-02.
5. NOTE: The connector is located at the front of
the traction battery on the right side.
Disconnect the four-pin high-voltage auxiliary
load connector.
WARNING: The nominal traction
100-00.
Pull out the red locking clip while pulling
apart the connector.
2001 Ranger EV, 01/2001
100-05-6
Section

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents