414-03B-129
REMOVAL AND INSTALLATION (Continued)
High Voltage/Traction Battery — Nickel Metal Hydride
10. NOTE: Two of the bolts secure hold down
brackets to the cover.
Remove the blower cover.
1 Remove the bolts.
2 Remove the cover.
11. NOTE: Note the location of the ''P'' clip that
retains the recirculating blower harness.
Remove the recirculating blower.
1 Remove the bolts.
2 Remove the blower
12. Remove the recirculating blower bracket.
1 Remove the bolts.
2 Remove the bracket.
Installation
1. To install, reverse the removal procedure.
414-03B-129