414-03A-109
REMOVAL AND INSTALLATION (Continued)
HVPDB Fuses
High Voltage/Traction Battery
Installation
1. To install, reverse the removal procedure.
•
Removal
1. Disconnect the traction battery auxiliary load
high-voltage connector. Refer to
100-05.
2. Remove the high-voltage power distribution box
(HVPDB) cover.
1 Remove the four screws.
2 Remove the cover.
Apply Locktite 242 to the 22 traction
battery cover bolts.
2001 Ranger EV, 01/2001
414-03A-109
Section