Ford Electric Ranger 2001 Manual page 540

Hide thumbs Also See for Electric Ranger 2001:
Table of Contents

Advertisement

414-03A-137
REMOVAL AND INSTALLATION (Continued)
High Voltage/Traction Battery
Removal
1. Remove the contactor box. Refer to
Box.
2.
the traction battery is 312 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
3. Remove battery modules 1-7.
4. Replace the faulty battery module(s). Refer to
Traction Battery Module
Installation
1. The battery module replacement procedure also
contains the battery module installation.
2. Install battery modules 1-7.
WARNING: The nominal voltage of
100-00.
Unclip and disconnect the heating element
electrical connectors.
Remove the separator plates.
Remove and discard the high-voltage jumper
retaining nuts.
Use the Battery Module Lifting Tool to
remove the battery modules.
Replacement.
Use the Battery Module Lifting Tool to
install the battery modules.
Install and tighten new battery module nuts
using the Battery Post Torque Wrench.
Install the separator plates.
Connect the heating element connectors.
Clip the connectors into the separator plate.
2001 Ranger EV, 01/2001