Ford Electric Ranger 2001 Manual page 522

Hide thumbs Also See for Electric Ranger 2001:
Table of Contents

Advertisement

414-03A-119
REMOVAL AND INSTALLATION (Continued)
High Voltage/Traction Battery
2. Remove the traction battery cover.
1 Remove the 22 bolts.
2 Remove the cover.
3.
the traction battery is 312 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4. Refer to the High-Voltage Jumper (HVJ) wiring
diagram to determine the location of the HVJ to
be replaced.
5. Remove the battery modules or components
necessary to gain access to the HVJ. Refer to
the procedures in this section.
6. NOTE: The sense lead is a thin orange wire
that is part of the HVJ.
Disconnect the sense lead connector for the
HVJ being removed.
WARNING: The nominal voltage of
100-00.
2001 Ranger EV, 01/2001