414-03B-117
REMOVAL AND INSTALLATION (Continued)
High Voltage/Traction Battery — Nickel Metal Hydride
2. Disconnect the traction battery high-voltage
two-pin connector. Refer to
WARNING: The nominal voltage of
3.
the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
100-00.
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4. Secure the two-pin high-voltage cable to the
rear axle to hold it out of the way.
5. Disconnect the 76-pin electrical connector.
1 Loosen the bolt.
2 Disconnect the electrical connector.
414-03B-117
Section
100-05.
2001 Ranger EV, 01/2001