414-03A-135
REMOVAL AND INSTALLATION (Continued)
Traction Battery Module — Modules 8-11
Special Tool(s)
Battery Module Lifting Tool
SR-10009
Battery Post Torque Wrench
307-026
High Voltage/Traction Battery
Removal
1.
the traction battery is 312 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
Section
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
2. Remove battery modules 4-6.
3. Replace the faulty battery module(s). Refer to
Traction Battery Module
WARNING: The nominal voltage of
100-00.
Unclip and disconnect the heating element
electrical connectors.
Remove the separator plates.
Remove and discard the high-voltage jumper
retaining nuts.
Use the Battery Module Lifting Tool to
remove the battery modules.
Replacement.
2001 Ranger EV, 01/2001