D-Link Dis-200G Series Cli Reference Manual page 40

Industrial gigabit ethernet switch
Hide thumbs Also See for Dis-200G Series:
Table of Contents

Advertisement

Parameters
INTERFACE ID
high
low
alarm
warning
mwatt VALUE
dbm VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 15.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid for this
configuration.
The no form of this command has the effect to clear the configured threshold stored in system.
Example
This example shows how to configure the RX power low warning threshold as 0.135 mW on interface eth1/0/11.
Switch# configure terminal
Switch(config)# transceiver-monitoring rx-power Ethernet 1/0/11 low warning mwatt
0.135
Switch(config)#
8-7 transceiver-monitoring temperature
This command is used to configure the temperature thresholds for the specified port. Use the no form of the
command to remove the configuration.
transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning}
Parameters
DIS-200G Series Gigabit Ethernet Switch CLI Reference Guide
Specifies the interface to modify.
Specifies that when the operating parameter rises above the
highest threshold, it indicates an abnormal status.
Specifies that when the operating parameter falls below the low
threshold this value, it indicates an abnormal status.
Specifies to configure the high and low threshold value condition.
Specifies to configure the high and low warning threshold
conditions.
Specifies the power threshold value in milliwatts. This value must
be between 0 and 6.5535.
Specifies the power threshold value in dBm. This value must be
between -40 and 8.1647.