● Edge Type
Shows the type of the connection. The following values are possible:
– Edge Port
– No Edge Port
● P.t.P. Type
Shows the type of the point-to-point link. The following values are possible:
– P.t.P.
– Shared Media
6.4.8

Ethernet Statistics

6.4.8.1

Interface Statistics

The page shows the statistics from the interface table of the Management Information Base
(MIB).
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
An edge port is connected to this port.
There is a spanning tree or rapid spanning tree device at this port.
With half duplex, a point-to-point link is assumed.
With a full duplex connection, a point-to-point link is not assumed.
Note
Point-to-point link means a direct connection between two devices. A shared media
connection is, for example, a connection to a hub.
Configuring with Web Based Management
6.4 "Information" menu
103