DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch Web UI Reference Guide
The fields that can be configured in Ethernet OAM DULD Settings are described below:
Parameter
Unit
From Port ~ To Port
Admin State
Action
Discovery Time
Click the Apply button to accept the changes made.
The fields that can be configured in Ethernet OAM DULD Table are described below:
Parameter
Unit
From Port ~ To Port
Click the Find button to locate a specific entry based on the information entered.
Click the View All button to display all the entries.

DDM

This folder contains windows that perform Digital Diagnostic Monitoring (DDM) functions on the Switch.
There are windows that allow the user to view the digital diagnostic monitoring status of SFP modules
inserting to the Switch and to configure alarm settings, warning settings, temperature threshold settings,
Figure 10-24 Ethernet OAM DULD Settings Window
Description
Select the switch's unit ID that will be used here.
Select the switch's port range that will be used here.
Select to enable or disable the admin state here. This feature is used
to enable Ethernet OAM unidirectional link detection on the specified
port(s).
Select the action that will be taken here. Options to choose from are
Normal and Shutdown.
Enter the discovery time value here. The range is from 5 to 65535
seconds. By default, this value is 5 seconds. If the OAM discovery
does not successfully negotiate before discovery time expired, OAM
unidirectional link detection will start.
Description
Select the switch's unit ID that will be used here.
Select the switch's port range that will be used here.