The fields that can be configured in Environment Trap Settings are described below:
Parameter
Fan Trap
Power Trap
Temperature Trap
Click the Apply button to accept the changes made.
The fields that can be configured in Environment Temperature Threshold Settings are described
below:
Parameter
Unit
Thermal
High Threshold
Low Threshold
Click the Apply button to accept the changes made.

Port Configuration

Port Settings

This window is used to view and configure the switch's port settings.
Figure 3-10 Peripheral Settings Window
Description
Click to enable or disable the fan trap state for waning fan event (fan
failed or fan recover).
Click to enable or disable the power trap state for waning power event
(power failed or power recover).
Click to enable or disable the temperature trap state for warning
temperature event (temperature exceeds the thresholds or
temperature recover).
Description
Select the switch unit that will be used for this configuration here.
Select the thermal sensor ID.
Enter the high threshold value of the warning temperature setting. The
range is from -100 to 200 Celsius degree. Tick the Default check box
to return to the default value.
Enter the low threshold value of the warning temperature setting. The
range is from -100 to 200 Celsius degree. Tick the Default check box
to return to the default value.
NOTE: The 10M and 100M speed options are only applicable when connecting to the
Management Port (Mgmt 0) or when the DXS-3600-EM-8T expansion module is
used.