K6Cm Setting Object (Class Id: 371 Hex) - Omron K6CM User Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

8-3-3

K6CM Setting Object (Class ID: 371 hex)

Service Code
Service code
02 hex
10 hex
01 hex
0E hex
Class ID
Specify 371 hex.
Instance ID
Specify 01 hex.
Attribute ID
 Common to K6CM
Attri-
Parameter
bute ID
name
64 hex
Software reset Restarts the K6CM device. It is used to
65 hex
Max./min.
reset
66 hex
Display value
type
67 hex
Trigger mode
68 hex
Trigger type
K6CM Motor Condition Monitoring Device User's Manual (N219)
Service name
Set_Attributes_All
Write values to all attributes.
Set_Attribute_Single
Write the value of the speci-
fied attribute.
Get_Attributes_All
Reads the values of all attri-
butes.
Get _Attribute_Single
Reads the value of the speci-
fied attribute.
Description
validate the setting after changing the set-
ting value.
Rising from 0 to 1: Execute (soft reset)
Initializes the MAX / MIN value.
OFF to ON: Execute (initialize max. and
min. value)
Sets which measurement value is dis-
played in the 7 segment display on the
front of the K6CM.
0: PV
1: MIN
2: MAX
Selects the trigger mode.
0: Always
1: External trigger
2: Internal trigger
Sets the trigger type.
0: Rising
1: Falling edge
2: Level
8 Monitoring and Setting with the EtherNet/IP
Description
Attri-
bute
Write
Write
Write
Write
Write
Supported services
Classes
Instances
Not supported.
Supported.
Not supported.
Supported.
Not supported.
Supported.
Not supported.
Supported.
Data
Data type
Default value
UINT
0
UINT
0
UINT
0
UINT
0
UINT
0
8 - 15
8