Power Supply Input Wiring - Omron K6CM User Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

4 Installation and Wiring
Wiring Diagram of the Comprehensive Current Diagnosis Type
(K6CM-CIM)
3 phase
voltage
fuse
Single phase
power supply
PLC etc.
Measurement trigger signal.
Computer,
PLC etc.
LAN
4-4-2

Power Supply Input Wiring

Wire the power supply to the K6CM devices.
Power supply input terminals are common to the K6CM devices. The power supply type varies depend-
ing on the type of K6CM device.
Power Supply Input Type
Depending on the type of K6CM device, the power type differs as follows.
Model
K6CM-A
K6CM-D
Terminal Wiring of Power Supply Input
(1) (2) Power supply input to the
K6CM device (24 VDC input: + - no polarity)
The power input terminals is the Push-In Plus Terminals.
4 - 22
CTK
1
7
CTL
2
8
3
4
DO NOT USE
DO NOT USE
K6CM-CIM
13
Transistor Output
14
15
Transistor Output
16
17
EtherNet/IP
Transistor Output
LAN
18
Power supply type
100 to 240 VAC
24 VAC/24 VDC
K6CM Motor Condition Monitoring Device User's Manual (N219)
Inverter
K(White)
*1 Measurable without a inverter
PLC etc.
PLC etc.
PLC etc.
(Upper part of K6CM device)
Monitor target
(motor etc.)
Dedicated CT
(K6CM-CIC)
L(Black)