Omron K6CM User Manual page 185

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

 Vibration & temperature type (K6CM-VBM)
Attri-
Parameter name
bute ID
6A hex
Acceleration status
6B hex
Acceleration (Present)
6C hex
Acceleration (Min.)
6D hex
Acceleration (Max.)
6E hex
Velocity status
6F hex
Velocity (Present)
70 hex
Velocity (Min.)
71 hex
Velocity (Max.)
72 hex
Motor temperature sta-
tus
73 hex
Motor temperature
(Present)
74 hex
Motor temperature (Min.) Monitored value of motor temperature (Min.) Read
75 hex
Motor temperature
(Max.)
76 hex
Temperature Gap status
77 hex
Temperature Gap (Pres-
ent)
78 hex
Temperature Gap (Min.)
79 hex
Temperature Gap (Max.)
 Insulation resistance type (K6CM-ISM)
Attri-
Parameter name
bute ID
6A hex
Insulation resistance sta-
tus
6B hex
Insulation resistance
(Present)
6C hex
Insulation resistance
(Min.)
6D hex
Insulation resistance
(Max.)
6E hex
Ior status
6F hex
Ior (Present)
70 hex
Ior (Min.)
K6CM Motor Condition Monitoring Device User's Manual (N219)
8 Monitoring and Setting with the EtherNet/IP
Description
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of acceleration (present
value)
Monitored value of acceleration (Min.)
Monitored value of acceleration (Max.)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of velocity (present value)
Monitored value of velocity (Min.)
Monitored value of velocity (Max.)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of motor temperature (pres-
ent value)
Monitored value of motor temperature
(Max.)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of temperature gap (pres-
ent value)
Monitored value of temperature gap (Min.)
Monitored value of temperature gap (Max.)
Description
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of insulation resistance
(present value)
Monitored value of insulation resistance
(Min.)
Monitored value of insulation resistance
(Max.)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of Ior (present value)
Monitored value of Ior (Min.)
Data
Attri-
Data
Default
bute
type
Read
UINT
0000 hex
*1
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
*1
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
*1
Read
UINT
0000 hex
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
*1
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Data
Attri-
Data
Default
bute
type
Read
UINT
0000 hex
*1
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
*1
Read
UINT
0000 hex
Read
UINT
0000 hex
value
8
value
8 - 13

Advertisement

Table of Contents
loading

Table of Contents