3-2-2

Detailed information on trigger mode and behavior by status

The operation of the K6CM device, trigger mode and state, and the operation results from the Motor
condition monitoring Tool and EtherNet/IP are as follows.
Trigger
Status
Measuring and
mode
Always
While the power
Measurement
is ON
and monitoring
External
Measuring and
No measuring
trigger
monitoring Not
and monitoring
input
yet
During measur-
Measurement
Or
ing and moni-
and monitoring
Internal
toring
trigger
After measur-
No measuring
ing and moni-
and monitoring
toring
*1. The measuring and monitoring status can be confirmed by "K6CM status" from EtherNet/IP.
 Example of Operation When the Trigger Mode Is "Always"
Measured value
Numeric LCD display
Status display
Automatic logging by tool
K6CM Motor Condition Monitoring Device User's Manual (N219)
3 Mechanism of Measuring and Monitoring of the K6CM Devices
K6CM device Operation
Front Numeric LCD
monitoring
Display
*1
status
Either the present
value, the minimum
value, or the maxi-
mum value of the
measurement value
"- - - -" is displayed
Either the present
value, the minimum
value, or the maxi-
mum value of the
measurement value
Holding and display-
ing values at the end
of measuring and
monitoring
Power ON
Measurement and monitoring period
(*1)
Measuring and monitoring
During measuring and monitoring
Either the current value, the minimum value,
or the maximum value of the measured value
With logging
*1.In the above figure, the power-ON state and the unmeasured state (i.e., the state until
the measured value is calculated) that exist immediately after turning ON the power
as shown on page 3-5 are omitted.
Operation results from the motor condition moni-
toring Tool and the EtherNet/IP
Motor condition monitor-
Status
ing Tool and read value
display
with the EtherNet/IP
"MON"
The present value, the mini-
mum value, and the maxi-
mum value of the
measurement value can be
read out individually
Not lit.
The read value is 0
"MON"
The present value, the mini-
mum value, and the maxi-
mum value of the
measurement value can be
read out individually
Not lit.
The held values are read out
at the end of the measuring
and monitoring
Power ON the next time
"MON"
Automatic logging
by the Motor condi-
tion monitoring Tool
Be executed
Be executed
Be executed
Be executed
Time
Measuring
and monitoring
During measuring
and monitoring
Either the current value,
the minimum value,
or the maximum value
of the measured value
"MON"
With logging
3 - 17