Individual Specifications Of The Sensor Used - Omron K6CM User Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

1-4-4

Individual specifications of the sensor used

K6CM-VBS Vibration & Temperature Sensor
 Model
Model
K6CM-VBS1
Note Vibration and temperature sensor consists of sensor head and pre-amplifier.The K6CM-VB1 is provided
with a magnet for positioning of the vibration & temperature.
 Ratings
Power supply voltage
Sensor head
Ambient operating temperature
Storage temperature
Ambient operating humidity
Storage humidity
Altitude
Case color
Case material
Weight
Mounting
Wire length
 Characteristics
Measurement range
Applicable stan-
dards
Insulation resistance
Dielectric strength
Vibration resis-
tance
Shock resistance
Degree of protec-
tion
Indicators
K6CM Motor Condition Monitoring Device User's Manual (N219)
Screw diameter
M6
Supplied from K6CM-VBM (Direct current)
Max. acceleration
10 G
Pre-amplifier: -10 to +55°C (with no condensation or icing)
Sensor head: -10 to +80°C (with no condensation or icing)
Pre-amplifier: -20 to +65°C (with no condensation or icing)
Sensor head: -20 to +90°C (with no condensation or icing)
25% to 85% RH (with no condensation)
25% to 85% RH (with no condensation)
2,000 m max.
Pre-amplifier: Black
Sensor head: Silver
Pre-amplifier: PC UL94-V0
Sensor head: ZDC2 (the threaded part is S45C)
Pre-amplifier: Approx. 210 g (including cable)
Sensor head: Approx. 40 g (including cable)
Pre-amplifier: DIN rail mounting, screw mounting
Sensor head: Screw mounting
Between pre-amplifier and sensor head: Connector connection
Between pre-amplifier and sensor head: 2.9 m (cannot be extended)
Between pre-amplifier and K6CM device: 1 m (can be extended up to a maxi-
mum length of 100 m)
Measurement range is described in the K6CM Individual Specifications.
EN61010-2-030
Conforming
Installation environment: Pollution degree 2, overvoltage category II, measure-
standards
ment category II
EMC
EN61326-1 (EMI: Class A EMS: Industrial Location)
UL61010-2-030 (listing)
Safety standards
Korean Radio Waves Act (Act 10564), RCM
20 MΩ min.
500 VAC for one minute
Vibration frequency 10 to 55 Hz, slice amplitude 0.35 mm in each of X, Y, Z
Pre-amplifier
directions 5 minute × 10 sweeps
Vibration frequency 10 to 55 Hz, slice amplitude 0.35 mm in each of X, Y, Z
Sensor head
directions 5 minute × 10 sweeps
Pre-amplifier
100 m/s
Sensor head
100 m/s
Pre-amplifier
IP20 (excluding the sensor-side cable)
Sensor head
Conforming to IP67G
Pre-amplifier PWR: Green, ERR: Red, COM: Orange
Connected K6CM
Vibration & temperature type (K6CM-VBM)
2
, 3 times each in 6 directions along 3 axes
2
, 3 times each in 6 directions along 3 axes
1 Overview
1
1 - 15