Data To Be Tag Data Link Target In The K6Cm Device - Omron K6CM User Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

8 Monitoring and Setting with the EtherNet/IP
8-2-2

Data to be Tag Data Link Target in the K6CM Device

Identification Number and Size of Internal Data to be Tag Data Link
The identification number (the instance ID of the Assembly object) and the size of internal data (Assem-
bly object) to be tag data link target in the K6CM device are as follows.
Identification number (Instance ID of
Assembly object)
100
List of Internal Data to be Tag Data Link
The tag data link target data in the K6CM device is shown below.
For each K6CM device, it is as follows.
In both cases, it is possible to read from the K6CM device to the originator such as PLC.
 Vibration & temperature type (K6CM-VBM)
Bit
Word
+0
+1
+2
+3
+4
+5
+6
+8
+9
+10
+11
+12
+13
+14
+15
+16
+17
+18
+19
+20
+21
8 - 8
44 bytes common to all models
15
14
13
12
11
Size
Target (K6CM type) → Originator
(such as PLC)
10
9
8
7
6
Measurement CPU version
Main CPU version
EIP CPU version
*1
K6CM status
Running Time
Number of triggers
*2
Acceleration status
Acceleration (Present)
Acceleration (Min.)
Acceleration (Max.)
*2
Velocity status
Velocity (Present)
Velocity (Min.)
Velocity (Max.)
Motor temperature status
Motor temperature (Present)
Motor temperature (Min.)
Motor temperature (Max.)
*2
Temperature Gap status
Temperature Gap (Min.)
Temperature Gap (Max.)
K6CM Motor Condition Monitoring Device User's Manual (N219)
Direction of data
5
4
3
2
1
*2
0

Advertisement

Table of Contents
loading

Table of Contents