Data name
In the case of an internal trigger or an external trigger, set the
time to continue monitoring when the trigger type rises or falls.
Monitoring
time
Setting value: 0.1 to 600.0 seconds.
It is common in case of internal trigger and external trigger.
Sets enable /disable of alarm latch function.
Alarm latch
0: Disable (no latch)
1: Enable (with latch)
Sets the usage or nonuse of K6CM remaining capacity func-
tion.
Use Run-
ning Time
0: OFF (not used)
1: ON (use)
Every time the measured value is sampled, the data of the past
n times including the sampling data of that time is averaged.
0: OFF
Moving
1: 2 times
average
2: 4 times
times
3: 8 times
4: 16 times
5: 32 times
Vibration & temperature Type (K6CM-VBM)
Data name
Sets the temperature unit.
Tempera-
0: °C
ture unit
1: °F
K6CM Motor Condition Monitoring Device User's Manual (N219)
6 Internal Data List of the K6CM Devices
Description
Description
Writing method (Yes: supported, No: sup-
ported)
Motor condi-
CIP mes-
tion moni-
sage com-
toring Tool
munications
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Writing method (Yes: supported, No: sup-
ported)
Motor condi-
CIP mes-
tion moni-
sage com-
toring Tool
munications
Yes
Yes
Tag data link
No
No
No
No
6
Tag data link
No
6 - 5