Omron K6CM User Manual page 46

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

2 Nomenclature and Functions
Name
Numeric LCD display
• When measuring and monitoring is started,
the measurement value is displayed.
Switching display of the monitoring cate-
gory on the right can be performed by
[DISP] key.
• With trigger (external trigger or internal trig-
ger), "- - - -" is displayed if measuring and
monitoring is not started yet. When the
measuring and monitoring is completed,
the measurement value just before the end
is retained and displayed.
Note : When the sensor is not connected, "-
For details, refer to Transition of Numeric LCD
Display on page 2-6.
Status display
K6CM device status is one of measuring and
monitoring in progress, self-diagnosis error,
operation summation status, with the LCD
character on the right.
Product and network sta-
Indicates the product status or network status
tus indications
by LEDs.
External trigger input
Trigger input by external input that sets the
K6CM device status during measuring and
monitoring (status display "MON").
Note : Insulation resistance type
Release the alarm latch (cancellation by
Front
[ARM RST]
operat-
Key
communication is impossible).
ing part
Note : Setting the alarm latch to "L" will latch
[DISP] Key
Switch the unit of measurement value (moni-
toring category)
Press the
When pressed at the same time for 5 seconds
[ALM RST]
or more, initialize all settings of the K6CM
and [DISP]
device and restore the Factory default.
Keys simulta-
neously
2 - 4
- - -" is displayed. When the input
range is over, 7 segments will flash
with the maximum value of the input
range.
(K6CM-ISM) is not acceptable.
the alarm condition of comprehensive
alarm (Warning or Critical) (alarm bar,
transistor outputs 1 and 2). Release
this latched state.
Meaning
• Acceleration, Velocity, Motor temperature, Difference
between Motor temperature and room temperature (Vibra-
tion & temperature type)
• Insulation resistance, Leakage current (Insulation resis-
tance type)
• Degradation level, current (Comprehensive current diagno-
sis type)
• "MON": Measuring and monitoring in progress
• "ERR": Self-diagnosis error occurrence
• "AGE": operation totalization notification (recommendation
for exchange of product body)
*1.
"MON" always lights up when there is no trigger. When
there is a trigger, it lights up during measuring and mon-
itoring. It turns off after measuring and monitoring is not
started yet, and after measuring and monitoring is com-
pleted (only when using the trigger function).
• "MS": ModuleStatus. Displays the status of the K6CM
device. It is green when it is normal.
• "NS": Network Status. Displays the state of the communica-
tions. It lights or flashes green when it is normal.
Note : For details, refer to Product and Network Status Indi-
cations Details on page 2-5.
Measuring and monitoring can be started at the rising edge of
OFF → ON or falling from ON → OFF, and measuring and
monitoring up to the specified time ([measurement time]), or
measuring and monitoring in the ON state can be selected .
If you press the [ALM RST] key during measuring and moni-
toring, it returns to the comprehensive alarm state at that point
(both the alarm bar and transistor outputs 1 and 2).
Every time it is pressed, the unit of measurement value
changes as follows.
• Vibration & temperature type: "G" → "mm/s" → "T" → "∆T"
(→ "G")
• Insulation resistance type: "MΩ" → "mA" (→ "MΩ")
• Comprehensive current diagnosis type: "Cim" → "A" (→
"Cim")
K6CM Motor Condition Monitoring Device User's Manual (N219)
*1
----

Advertisement

Table of Contents
loading

Table of Contents