List Of Models; Models Of K6Cm Device - Omron K6CM User Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

1 Overview
1-2

List of Models

This section shows the models of K6CM device and the sensors to be used.
1-2-1

Models of K6CM Device

The monitor types of K6CM device are as follows.
Monitor Types
Monitor type
Vibration & tempera-
ture type
Insulation resis-
tance type
Comprehensive cur-
rent diagnosis type
*1. Measuring the magnitude of vibration of things are displacement, velocity, and acceleration. Displacement in-
dicates how far it moved. The velocity shows how fast it moves, and the acceleration shows how fast it has
reached that velocity. In the K6CM-VBM, velocity and acceleration can be measured.
*2. The motor temperature is measured with the sensor head, and the room temperature is measured by the tem-
perature sensor inside the pre-amplifier.
*3. The insulation resistance value measured by the insulation resistance type may be different from the measure-
ment value with the insulation resistance meter.
*4. Leakage current includes Ior and Ioc. The relationship between Ioc and Ior is shown below.
Ioc
With the K6CM-ISM, only Ior (resistance leakage current) can be measured (alarm monitoring can not be per-
formed). There is no indication on the front of the K6CM device for Ioc (leakage current due to capacitance).
It can be read out with Motor condition monitoring Tool or EtherNet/IP.
*5. The K6CM-CIM measures the degree of normality/fault of the motor from the motor current waveform. The low-
er the degradation level, the better the motor is in the normal condition.
1 - 4
Model
K6CM-VBM Vibration acceleration*1, vibration velocity*1, motor
temperature, temperature gap (i.e., difference
between motor temperature and room temperature)*2
K6CM-ISM
Insulation resistance*3, leakage current (i.e., Ior,
Ioc)*4
K6CM-CIM
Degradation level*5, current
Io
Io: Leakage current
Ior: Leakage current component due to insulation resistance deterioration in Io
Ioc: Leakage current component due to ground capacitance in Io
Ior
Measurement value
K6CM Motor Condition Monitoring Device User's Manual (N219)