8 Monitoring and Setting with the EtherNet/IP
Attri-
Parameter name
bute ID
71 hex
Ior (Max.)
72 hex
Ioc status
73 hex
Ioc (Present)
 Comprehensive current diagnosis type (K6CM-CIM)
Attri-
Parameter name
bute ID
6A hex
Current status
6B hex
Current (Present)
6C hex
Current (Min.)
6D hex
Current (Max.)
6E hex
Degradation level status
6F hex
Degradation level (Pres-
ent)
70 hex
Degradation level (Min.)
71 hex
Degradation level (MAX)
*1. Measurement status (common form of measured value)
Bit position
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Precautions for Correct Use
In case of no trigger, read the data when "Present value measurement state" bit (bit 00) of the
individual measuring and monitoring status is 0. If reading is performed when the "Present
value measurement state" bit is 1 (ON), there is a possibility that the value (i.e., 0) before mea-
suring and monitoring is being read.
8 - 14
Monitored value of a Ior (Max.)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of Ioc (present value)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of current (present value)
Monitored value of current (Min.)
Monitored value of current (Max.)
Displays the measurement status.
For details, refer to "Measurement status
(common form of measured value)".
Monitored value of degradation level (pres-
ent value)
Monitored value of degradation level (Min.)
Monitored value of degradation level (Max.)
Status
Present value unmeasured state
Present value input error
Reserved.
Reserved.
Maximum value unmeasured state
Maximum value input error
Reserved.
Reserved.
Minimum value unmeasured state
Minimum value input error
Reserved.
Reserved.
Individual alarm result (Warning)
Individual alarm result (Critical)
Reserved.
Reserved.
Description
*1
Description
*1
*1
Measured status
Not occurred
Measured status
Not occurred
Measured status
Not occurred
OFF
OFF
K6CM Motor Condition Monitoring Device User's Manual (N219)
Data
Attri-
Data
Default
bute
type
value
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Data
Attri-
Data
Default
bute
type
value
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Read
UINT
0000 hex
Bit content
0
1
Unmeasured status
Occurrence
Unmeasured status
Occurrence
Unmeasured status
Occurrence
ON
ON