Omron K6CM User Manual page 50

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

2 Nomenclature and Functions
Nomenclature and functions of the pre-amplifier
To the sensor head
To the K6CM-VBM
Vibration &
temperature type
Nomenclature and functions of the sensor head
To the pre-amplifier
Cable part
M6 screw
2 - 8
LED
PWR
ERR
COM
PWR LED
ERR LED
COM LED
Terminal number of
the K6CM device
At the top of the armor of the induction motor, cut the tap into which
the M6 screw vertically enters, screw it in and install it.
The position of the tap is recommended above the bearing of the
induction motor.
When installing, removing the connector of the cable facilitates
handling.
For the M6 type, a magnet for positioning is enclosed.
Name
Color
Pre-amplifier power
Green
supply
----
Pre-amplifier fault
Red
Communication
Orange
between pre-amplifier
and K6CM
Vibration & temperature sensor
side
7
VBS 0: Sensor input (+)
8
VBS 1: Sensor input (-)
9
VBS 2: Supply to sensor 10 V (+)
10
VBS 3: Supply to sensor 10 V (-)
K6CM Motor Condition Monitoring Device User's Manual (N219)
Status
Operating condition
Lit.
Normal status
Not lit.
Power not supplied
Lit.
Self-diagnosis error
occurred
Lit.
STX transmission, lit
at reception 50 ms
Line color
Red and white
Red
Black
Black and white

Advertisement

Table of Contents
loading

Table of Contents