(24) Do not mount the way that the force is directly applied to the fitting part of the connector or the root
part of the cable connection. It may result in connector damage or cable disconnection.
(25) When bending cables, use cables with a minimum bending radius of 25 mm.
(26) Use preamplifier after it is fixed on the DIN rail or with screws. In case of using unfixed one, it is in
the condition that force is easily applied to the cable, and the cable may be broken.
(27) About oil-resistance of sensor head/cable; (Not tested by UL)
Follow the procedure below in case of using the product under the condition that uses cutting oil
since the life expectancy and the performance of the product are affected.
• Use the product in the specified condition for cutting oil
• Use the product at the dilution rate of cutting oil that is recommended by the cutting oil makers.
• Do not use the product in oil or water.
There are cases that the influence on the life expectancy of the product differs depending on the
type of the use oil. Make sure in advance that there is no deterioration of the sealing material by the
cutting oil, before using the product.
The followings are for K6CM-IS and K6CM-CI.
(28) Error will be large if the product is used for thyristor control.
(29) Do not use the alarm output function for control. This function can be used only to detect abnormal
conditions and to output the alarm.
(30) Avoid using the product in places near a radio, a television set, or a wireless device.
The product may result in radio disturbance for these devices.
(31) Make sure that the rating of the used CT and the CT setting of the product agree.
(32) Do not ground the specified CT. Doing so may cause instability when measuring failure.
(33) Do not clamp directly to the lines exceeding 600 VAC.
(34) Use ZCT (IRT) after fixing it with screws. If used without fixing, a load is easily applied on the cable,
and the cable may become disconnected.
The followings are only for K6CM-IS.
(35) ZCT (IRT) is an special product. Do not use it for any other purposes. Otherwise, failure may occur.
(36) When clamping wires with ZCT (IRT), do it in a right direction. If clamped in the wrong direction,
correct measurement cannot be taken.
(37) The distorted ratio of the input waveform should be 30% or less. If it is used in a circuit with large
distortion of waveform, it may cause unnecessary operation.
(38) Do not use in a circuit with the waveform is distorted. The error will increase due to the influence of
the distorted waveform.