Procedure for Setting IP Address (when necessary, further
parameters)
The IP address of each K6CM device is set by the following procedure. It is also possible to set further
parameters when necessary.
The initial value of the IP address of the K6CM device is "192.168.250.10" common to all models.
1
Directly connect the Motor condition monitoring Tool to the K6CM device one-on-one using the
Ethernet cable.
2
Start the Motor condition monitoring tool.
The following startup screen will be displayed.
3
Select [Device setting].
The following SYSMAC Gateway Console screen is displayed.
(1) Confirm that [Startup] in the [Communication Service] field is "Auto" and that [Status] is cur-
rently "Start".
Note The communication service of Sysmac Gateway is in the starting state at the same time that
(2) Set the network port to which you want to connect in the [Network Port] field.
Note If you set multiple ports, the port with the smallest ID number in the [Port ID] column is auto-
K6CM Motor Condition Monitoring Device User's Manual (N219)
5 Setting with the Motor condition monitoring Tool
Windows starts, when [Startup] on the Sysmac Gateway Console screen is "Auto".
matically used.
5
5 - 37