K6Cm Devices - Omron K6CM User Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

 When There Is a Trigger (external trigger or internal trigger)
The alarm bar turns off, the numeric LCD display shows "- - - -", and the transistor outputs 1 and 2
are both OFF until measuring and monitoring is started (when measuring and monitoring is not
started yet).
During measuring and monitoring, the state is the same as when the trigger mode is always (no trig-
ger).
After measuring and monitoring, the state at the time of measuring and monitoring end is maintained
for alarm bar, numeric LCD display, transistor output 1 and 2.
Measured value
Critical level
A
Warning level
Power ON
(*1)
Alarm bar
Numeric LCD display
Status display
ON
Transistor Output 1
OFF
ON
Transistor Output 2
OFF
*1. In the above figure, the power-ON state and the unmeasured state (i.e., the state until the mea-
K6CM Motor Condition Monitoring Device User's Manual (N219)
3 Mechanism of Measuring and Monitoring of the K6CM Devices
Start measuring and monitoring
Measuring and
monitoring Not yet
No lit.
Green
Yellow
"- - - -"
No lit.
sured value is calculated) that exist immediately after turning ON the power as shown on page
3-5 are omitted.
End measuring and monitoring
During measuring
After measuring
and monitoring
and monitoring
Red
Yellow
Yellow (keep)
Measured value displayed
"MON"
Keep OFF
Keep ON
Time
It returns to the
"measuring and
A (keep)
monitoring not
yet" state when
No lit.
the ALM RST key
is pressed.
3
3 - 7

Advertisement

Table of Contents
loading

Table of Contents