Starting point: the status display

When you switch on an easySafety device, it opens the
status display immediately. This status display shows the
P-
switching state of the inputs and outputs and also indicates
whether the device is currently running a (safety) circuit
diagram.
Requirement for circuit diagram entry: the easySafety
device must be in STOP mode.
h
The examples do not involve the use of expansion devices.
If an expansion unit is connected, the status display will
first show the status of the basic unit and then the status
of the expansion unit before showing the first selection
menu.
Press OK to switch to the main menu.
X
The SECURITY menu option is selected on the easySafety
device.
In general, press OK to switch to the next menu level, and
press ESC to move one level back.
h
OK has two other functions:
• Press OK to transfer the modified setting values in Entry
mode.
• In the circuit diagram, you can also press OK to insert
and modify contacts and relay coils.